MIX Bed for RO plant

Usually a mixed bed unit contains strong acid Cation (SAC) resin and strong base Anion (SBA) resins combined to a ratio of approximately 40% Cation resin to 60% Anion resin. (All resin volumes are dependent upon the feed water analysis and the required quantity of treated water).

Mixed bed polishers are typically installed when a water quality of less than 1 micro ohm conductivity is required. Normally mixed bed polishers are installed after a standard Reverse Osmosis or De mineraliser (DM Plant), to produce ultra high quality water.

The Cation resins in mixed bed units are of a higher specific gravity and settle at the bottom of the vessel at the same time the Anion resin will automatically float to the top.

Please note: The Cation resin must be a strong acid Cation type (SAC) and the Anion resin must be a strong base Anion resin (SBA)

After a service cycle, each resin is regenerated as below:

  • (SAC) : Strong Acid Cation resin is washed with approx. 30% hydrochloric acid.
  • (SBA) : Strong Base Anion is washed with approx. 26% caustic.

Please note: The above regenerate strengths refer to the values before being diluted by the mixed bed unit educator systems.